I am looking for partners in the research area.

I am looking for partners interested in the Horizon Europe Call.

I am looking for partners for the Horizon Europe research area.

I am looking for laboratory facilities in the research/application area.

Associate Professor

Dr. Imre Szalóki

PhD

H-1111Műegyetem rkp. 9., TR building

+3614631566

+36209615986

szaloki@reak.bme.hu

Publications

1. I. Szalóki, A. Gerényi, G. Radócz, A. Lovas, B. De Samber, L. Vincze, FPM model calculation for micro X-ray fluorescence confocal imaging using synchrotron radiation, Journal of Analytical Atomic Spectrometry, 32, 334-344, 2017, 10.1039/C6JA00161k.
2. I. Szalóki, A. Gerényi, G. Radócz, Confocal macro X-ray fluorescence spectrometer on commercial 3D printer, X-ray Spectrometry, 46, 497-506, 2017, 10.1002/xrs.2781
3. I. Szalóki, T. Pintér, jnr. I. Szalóki, G. Radócz, A. Gerényi, A novel confocal XRF-Raman spectrometer and FPM model for analysis of solid objects and liquid substances, Journal of Analytical Atomic Spectrometry, 2019, 10.1039/c9ja00044e.
4. I. Szalóki, G. Radócz, A. Gerényi, Reverse Monte Carlo iterative algorithm for quantification of x-ray fluorescence analysis based on MCNP6 simulation code, X-Ray Spectrometry, 49, 587-595, 2020, 10.1002/xrs.3154.
5. I. Szalóki, A. Gerényi, F. Fodor, G. Radócz, V. Czech, L. Vincze, Improved Micro-X-ray Fluorescence Confocal Imaging of Two-Dimensional Distribution of Arsenic Concentration in Cucumber Hypocotyls Using Synchrotron Radiation, Analytical Chemistry, 93, 11660 − 11668, 2021, 10.1021/acs.analchem.1c00579.

Awards

---

Projects

1. Synchrotron based research projects and beam time at DESY Doris L beamline:
II-20060097-2006-2009, Micro tomography and micro X-ray fluorescence analysis on biological samples to investigate toxicity processes.
II-20090137-2009-2010, Development of methodology and experimental conditions of X-ray fluorescence tomography and confocal imaging to study the microstructure and elementary maps of biological objects.
II-20110256EC-2011-2012, DESY Doris L: Development of experimental methods of 3D X-ray fluorescence micro tomography and application for study of metal toxicity effects, Development of XANES method for determination of arsenic chemical form in biological samples.
2. VKSZ-14-1-2015-0021 Hungarian project supported by the National Research, Development and Innovation Found, National Nuclear Research Project, VKSZ_14-1-2015-0021, 3.1.5, Development nuclear analytical methods, 2015-2018.
3. MVM Paks NPP R+D project: Primary-secondary leakage review of steam generators, 2014-2015.
4. Hungarian Atomic Energy Authority, Development of a portable gamma-ray spectrometer and a method for the simultaneous quantitative analysis of elemental composition and isotope-selective radioactivity of materials. Determination of the alpha emitting fissile material content of samples and the methodological development of the radiochemical procedure, 2014-2017.
5. MVM Paks NPP R+D project: Development of model calculations and algorithm for the determination of the time-dependent isotopic composition, burn-up and operating age of defected fuel elements, 2013-2016. Development of theoretical model and numerical calculations for the simultaneous determination of radioisotopes in fuel elements and coolant depending on operating parameters to the leakage status of fuel elements and the improvement of inspection efficiency for liquid radioactive waste, 2017-2018.
6. MVM ERBE Power Engineering and Consulting Private Company Limited, Development of leakage model calculations for steady-state and transient operating conditions for VVER-1200 reactors, (2017-2018). Control manual for primary and secondary water chemistry in VVER-1200 nuclear reactors, 2019-2021.
7. MVM Paks NPP R+D project, Centre for Energy Research, Control manual: Leakage fuels in VVER-440 reactors, 2020-2021.

Conferences

1. I. Szalóki, G. Radócz , A. Gerényi, Simultaneous application of SDD and CZT detectors in combined X-ray fluorescence and gamma spectrometer, IWORID, 2016, International Workshop on Radiation Imaging Detectors, Barcelona, Spain, AXA Convention Center, 3-7 July 2016.
2. I. Szalóki, G. Radócz, A. Gerényi, Confocal X-ray fluorescence spectrometer and commercial 3D printer, EXRS 2016, European Conference on X-Ray Spectrometry, EXRS2016, Gothenburg, June 19-24, 2016.
3. A. Gerényi, G. Radócz, I. Szalóki, Simultaneous application of X-Ray fluorescence and gamma spectrometer for analysis of radioactive waste material, 26th Symposium of AER on VVER Reactor Physics and Reactor Safety, Helsinki 10.-14. Oct, 2016, p. 617 ISBN: 978-963-7351-27-3
4. G. Radócz, A. Gerényi, I. Szalóki, Monte Carlo based efficiency calibration of portable Cube527 CdZnTe micro spectrometer for gamma spectrometry of radioactive waste material, IWORID 2017, 19th International Workshop on Radiation Imaging Detectors, Krakkov, AGH University of Science and Technology Faculty of Physics and Applied Computer Science Building D-10 Reymonta St. 1930-059 Krakow, Poland, 2017.07.02.-2017.07.06.
5. I. Szalóki, G. Radócz, A. Gerényi, X-ray fluorescence microanalysis of cucumber hypocotyls using synchrotron radiation, CSIXL, Colloquium Spectroscopicum Internationale XL, Olaszország, Pisa, CSI-XL, Palazzo dei Congressi, Via Giacomo Matteotti, 1, 56124 Pisa, Italy 2017.06.11-2017.06.16.
6. I. Szalóki, G. Radócz, A. Gerényi, Analytical characterization of 3D confocal macro X-ray fluorescence spectrometer, European Conference on X-Ray Spectrometry, Ljubljana, Szlovénia, 2018.06.24 - 06.29.
7. G. Radócz, A. Gerényi, I. Szalóki, Characterization of a portable Cube527 CdZnTe micro gamma spectrometer for Monte Carlo based efficiency calibration of in situ gamma spectrometry on radioactive waste materials, Symposium on International Safeguards: Building Future Safeguards Capabilities, IAEA, Bécs, Ausztria, 2018.11.05 - 2018.11.09.
8. I. Szalóki, G. Radócz, A. Gerényi, Development of a new confocal-macro X-ray fluorescence spectrometer built on 3D printer, Symposium on International Safeguards: Building Future Safeguards Capabilities, IAEA, Bécs, Ausztria, 2018.11.05 - 11.09.
9. I. Szalóki, G. Radócz, T. Pintér, P. J. Rozmanitz, I. V. Baracska, A. Gerényi, Time dependent leakage model to identify defective fuel assemblies in VVER-type nuclear reactors, 29th Symposium of AER on VVER Reactor Physics and Reactor Safety, Energoland Mochovce, Mochovce NPP, Slovakia, October 14 – 18, 2019.
10. Cs. Szarvas, G. Radócz, A. Gerényi, P. J. Rozmanitz, I. Szalóki, Development of a time-dependent leakage process model of defected fuels of VVER-type nuclear reactors, The European Physical Society Forum, https://epsforum.org/, Párizs, Sorbonne Université, 2022.07.02-07.04.
11. I. Szalóki, A. Gerényi, Cs. Szarvas, G. Radócz, Development of Reverse Monte Carlo algorithm for quantification procedure of X-ray fluorescence analysis using MCNP6 software package, European Conference on X-ray Spectrometry 2022, EXRS-2022, Bruges, Belgium, 2022.26.06 – 01.07.

Patents

---

Other activities

---