I am looking for partners in the research area.

I am looking for partners interested in the Horizon Europe Call.

I am looking for partners for the Horizon Europe research area.

I am looking for laboratory facilities in the research/application area.

Assistant Professor

Dr. Anita Gerényi

PhD

H-1111 Budapest, Műegyetem rkp. 9., TR building, Department of Atomic Energy, Institute of Nuclear Techniques

+3614631252

gerenyi@reak.bme.hu

Publications

1. I. Szalóki, A. Gerényi, G. Radócz, A. Lovas, B. De Samber, L. Vincze, FPM model
calculation for micro X-ray fluorescence confocal imaging using synchrotron radiation,
Journal of Analytical Atomic Spectrometry, 32, 334-344, 2017, 10.1039/C6JA00161k.
2. I. Szalóki, A. Gerényi, G. Radócz, Confocal macro X-ray fluorescence spectrometer on
commercial 3D printer, X-ray Spectrometry, 46, 497-506, 2017, 10.1002/xrs.2781
3. Gerényi, A ; Czech, V ; Fodor, F ; Vincze, L ; Szalóki, I, In vivo XANES measuring technique for studying the arsenic uptake in cucumber plants, X-RAY SPECTROMETRY 46 : 3 pp. 143-150. , 8 p., 2017, 10.1002/xrs.2730
4. I. Szalóki, T. Pintér, jnr. I. Szalóki, G. Radócz, A. Gerényi, A novel confocal XRF-
Raman spectrometer and FPM model for analysis of solid objects and liquid substances,
Journal of Analytical Atomic Spectrometry, 2019, 10.1039/c9ja00044e.
5. I. Szalóki, A. Gerényi, F. Fodor, G. Radócz, V. Czech, L. Vincze, Improved Micro-X-ray
Fluorescence Confocal Imaging of Two-Dimensional Distribution of Arsenic
Concentration in Cucumber Hypocotyls Using Synchrotron Radiation, Analytical
Chemistry, 93, 11660 − 11668, 2021, 10.1021/acs.analchem.1c00579.

Projects

1. Synchrotron based research projects and beam time at DESY Doris L beamline:
II-20090137-2009-2010, Development of methodology and experimental conditions of
X-ray fluorescence tomography and confocal imaging to study the microstructure and
elementary maps of biological objects.
II-20110256EC-2011-2012, DESY Doris L: Development of experimental methods of
3D X-ray fluorescence micro tomography and application for study of metal toxicity
effects, Development of XANES method for determination of arsenic chemical form in
biological samples.
2. VKSZ-14-1-2015-0021 Hungarian project supported by the National Research,
Development and Innovation Found, National Nuclear Research Project, VKSZ_14-1-
2015-0021, 3.1.5, Development nuclear analytical methods, 2015-2018.
3. MVM Paks NPP R+D project: Primary-secondary leakage review of steam generators,
2014-2015.
4. Hungarian Atomic Energy Authority, Development of a portable gamma-ray
spectrometer and a method for the simultaneous quantitative analysis of elemental
composition and isotope-selective radioactivity of materials. Determination of the alpha
emitting fissile material content of samples and the methodological development of the
radiochemical procedure, 2014-2017.
5. MVM Paks NPP R+D project: Development of model calculations and algorithm for the
determination of the time-dependent isotopic composition, burn-up and operating age of
defected fuel elements, 2013-2016. Development of theoretical model and numerical
calculations for the simultaneous determination of radioisotopes in fuel elements and
coolant depending on operating parameters to the leakage status of fuel elements and the
improvement of inspection efficiency for liquid radioactive waste, 2017-2018.
6. MVM ERBE Power Engineering and Consulting Private Company Limited,
Development of leakage model calculations for steady-state and transient operating
conditions for VVER-1200 reactors, (2017-2018). Control manual for primary and
secondary water chemistry in VVER-1200 nuclear reactors, 2019-2021.

Conferences

1. Szalóki, G. Radócz , A. Gerényi, Simultaneous application of SDD and CZT detectors
in combined X-ray fluorescence and gamma spectrometer, IWORID, 2016,
International Workshop on Radiation Imaging Detectors, Barcelona, Spain, AXA
Convention Center, 3-7 July 2016.
2. Szalóki, G. Radócz, A. Gerényi, Confocal X-ray fluorescence spectrometer and
commercial 3D printer, EXRS 2016, European Conference on X-Ray Spectrometry,
EXRS2016, Gothenburg, June 19-24, 2016.
3. A. Gerényi, G. Radócz, I. Szalóki, Simultaneous application of X-Ray fluorescence and
gamma spectrometer for analysis of radioactive waste material, 26th Symposium of
AER on VVER Reactor Physics and Reactor Safety, Helsinki 10.-14. Oct, 2016, p. 617
ISBN: 978-963-7351-27-3,
4. I. Szalóki, G. Radócz, A. Gerényi, X-ray fluorescence microanalysis of cucumber
hypocotyls using synchrotron radiation, CSIXL, Colloquium Spectroscopicum
Internationale XL, Olaszország, Pisa, CSI-XL, Palazzo dei Congressi, Via Giacomo
Matteotti, 1, 56124 Pisa, Italy 2017.06.11-2017.06.16.,
5. I. Szalóki, G. Radócz, A. Gerényi, Analytical characterization of 3D confocal macro X-
ray fluorescence spectrometer, European Conference on X-Ray Spectrometry,
Ljubljana, Szlovénia, 2018.06.24 - 06.29.
6. G. Radócz, A. Gerényi, I. Szalóki, Characterization of a portable Cube527 CdZnTe
micro gamma spectrometer for Monte Carlo based efficiency calibration of in situ
gamma spectrometry on radioactive waste materials, Symposium on International
Safeguards: Building Future Safeguards Capabilities, IAEA, Bécs, Ausztria, 2018.11.05
- 2018.11.09.
7. I. Szalóki, G. Radócz, A. Gerényi, Development of a new confocal-macro X-ray
fluorescence spectrometer built on 3D printer, Symposium on International Safeguards:
Building Future Safeguards Capabilities, IAEA, Bécs, Ausztria, 2018.11.05 - 11.09., előadás
8. I. Szalóki, G. Radócz, T. Pintér, P. J. Rozmanitz, I. V. Baracska, A. Gerényi, Time
dependent leakage model to identify defective fuel assemblies in VVER-type nuclear
reactors, 29th Symposium of AER on VVER Reactor Physics and Reactor Safety,
Energoland Mochovce, Mochovce NPP, Slovakia, October 14 – 18, 2019., előadás
9. I. Szalóki, A. Gerényi, Cs. Szarvas, G. Radócz, Development of Reverse Monte Carlo
algorithm for quantification procedure of X-ray fluorescence analysis using MCNP6
software package, European Conference on X-ray Spectrometry 2022, EXRS-2022,
Bruges, Belgium, 2022.26.06 – 01.07.